DSA system management test results
The following messages can result when you run the system management test.
166-000-001 IMM I2C Test Passed
Explanation: IMM I2C Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
166-801-001 IMM I2C Test Aborted
Explanation: IMM returned incorrect response length.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-802-001 IMM I2C Test Aborted
Explanation: Test cannot be completed for unknown reason.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-000-001 166-802-001
Appendix C. DSA diagnostic test results 767

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M4
CategoryServer
LanguageEnglish

Related product manuals