DSA system management test results
The following messages can result when you run the system management test.
166-000-001 IMM I2C Test Passed
Explanation: IMM I2C Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
166-801-001 IMM I2C Test Aborted
Explanation: IMM returned incorrect response length.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-802-001 IMM I2C Test Aborted
Explanation: Test cannot be completed for unknown reason.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
166-000-001 • 166-802-001
Appendix C. DSA diagnostic test results 767