202-802-000 MemStr Test Aborted
Explanation: Memory size is insufficient to run the test. At least 1 GB is required.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
202-803-000 MemStr Test Aborted
Explanation: User pressed Ctrl-C.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
202-901-000 MemStr Test Failed
Explanation: Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Execute the standard DSA memory diagnostics to validate all memory.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system on.
6. Run the test again.
7. Execute the standard DSA memory diagnostics to validate all memory.
8. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
202-802-000 202-901-000
Appendix C. DSA diagnostic test results 759

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M4
CategoryServer
LanguageEnglish

Related product manuals