EasyManua.ls Logo

IBM System x3550 M4 - Page 416

IBM System x3550 M4
820 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80010b01-0c01xxxx Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (Ambient Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b010c01xxxx or 0x80010b010c01xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1001xxxx Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PCI Riser 1 Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011001xxxx or 0x80010b011001xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1002xxxx Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PCI Riser 2 Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011002xxxx or 0x80010b011002xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-0c01xxxx 80010b01-1002xxxx
398
IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Related product manuals