80070603-0701xxxx Sensor [SensorElementName] has transitioned to non-recoverable. (Pwr Rail 1-6 Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706030701xxxx or 0x800706030701xxxx
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is one of Pwr Rail 1-6 Fault, please follow actions in "Power Problems and
Solving Power Problems".
80070608-0a01xxxx Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a01xxxx or 0x800706080a01xxxx
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is
solved:
1. Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Replace power supply n. (n = power supply number)
80070603-0701xxxx • 80070608-0a01xxxx
Appendix A. Integrated management module II (IMM2) error messages 411