816f000d-0406xxxx The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 6)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0406xxxx or 0x816f000d0406xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-0407xxxx The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 7)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0407xxxx or 0x816f000d0407xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-0406xxxx 816f000d-0407xxxx