W.3048006 [W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event.
Explanation: Automated Boot Recovery, Booting Backup UEFI Image
Severity: Warning
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this product.
3. (Trained service technician only) Replace the system board.
W.305000A [W.305000A] An invalid date and time have been detected.
Explanation: RTC Date and Time Incorrect
Severity: Warning
User response: Complete the following steps:
1. Check IMM/chassis event log. This event should immediately precede 0068002 error. Service that event or any
other battery related errors.
2. Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS battery.
3. If problem persists then check IBM support site for an applicable service bulletin or firmware update that applies
to this error.
4. Trained Service technician only) Replace the system board.
W.3058009 [W.3058009] DRIVER HEALTH PROTOCOL: Missing Configuraiton. Requires Change Settings From
F1.
Explanation: DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1
Severity: Warning
User response: Complete the following steps:
1. Go to System Settings > Settings > Driver Health Status List and find a driver/controller reporting Configuration
Required status.
2. Search for the driver menu from System Settings and change settings appropriately.
3. Save settings and restart system.
W.305800A [W.305800A] DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Explanation: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller
Severity: Warning
User response: Complete the following steps:
1. Reboot the system.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
W.3048006 W.305800A
678
IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
ProcessorIntel Xeon E5-2600 series
ChipsetIntel C600 series
MemoryUp to 768 GB
StorageUp to 8 x 2.5" hot-swap drives
Form Factor1U rack
Power Supply750 W AC
Network Interface4 x 1 GbE
RAID SupportRAID 0, 1, 10
Expansion Slots3 x PCIe 3.0 slots
Operating System SupportWindows Server, RHEL, SUSE, VMware
ManagementIntegrated Management Module II (IMM2)

Related product manuals