218-806-000 Brocade:InternalLoopbackTest Aborted
Explanation: The test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
218-900-000 Brocade:MemoryTest Failed
Explanation: A failure was detected while testing the adapter memory.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
218-901-000 Brocade:ExternalLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.