409-804-000 Nvidia::DiagnosticServiceProvider::Query Test Aborted
Explanation: Nvidia GPU Query test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
409-805-000 Nvidia::DiagnosticServiceProvider::Matrix Test Aborted
Explanation: Nvidia GPU Matrix test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
409-806-000 Nvidia::DiagnosticServiceProvider::Binomial Test Aborted
Explanation: Nvidia GPU Binomial test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
409-900-000 NVIDIA User Diagnostic Test Failed
Explanation: NVIDIA User Diagnostic Test Failed.
Severity: Event
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
409-804-000 • 409-900-000
762
IBM System x3550 M4 Type 7914: Installation and Service Guide