52 PRT-KLCD Protege Alphanumeric LCD Keypad User Manual | April 2011
11 Elevator Groups
Elevator groups are used to define what elevators a user will be able to access and/or control. A elevator group is
assigned to an access level (see page 38) to restrict the ability for a user to use certain elevato
rs. For example
service elevators can only be used by service staff restricting them access to the public elevators. The Protege
system supports up to 250 elevator groups.
11.1 All Elevators Group
The All Elevators group is a special elevator group that allows access to all elevators within the system. The All
Elevators group is assigned to the master access level by default.
Changing the All Elevators group is not recommended as it will restrict access to the elevators used by
the Master Access Level.
11.2 Program Elevator Groups
Elevator groups should be programmed so that they are used for a group of users, for example administration,
legal department, butler service, maintenance and management where the groups can clearly be identified by the
elevators that they need to access.
Programming Elevator Groups
Enter your [USER CODE] to logon to the keypad.
In the example elevator group configuration elevator group EG010 is being edited. Modifying the
All
Elevators
group is not recommended.
Elevator grp to
modify: EG001
Select the elevator group add/modify sub menu item located in the main menu [MENU,2,7]. This will take you to
the screen asking to select an elevator group number to modify. The first elevator group number will be shown.
The cursor will be located over the first number.
EG010 Name
Service Team
The cursor will be positioned at the start of the elevator group name entry. To modify the name use the numerical
keys. Press [ENTER] key to save the name and move to the next programming screen. Press the [DISARM] key
to clear the name or to recall the current name press the [ARM] key.
EG010 ScheduleÎ