20
3.8.5 Menu – DHW – Status – Real time
values – Sensors
Once sensors is selected the screen will
show the congured list of Domestic Hot
Watercircuits:
Sensors
DHW1 Boiler 1
Once a DHW circuit is selected, then the
following screen will display the current
Realtimevaluesfortheconguredsensors,
onceagainitemsthatarenotconguredwill
beshownwithnovaluebutwith2dashes
to indicate this, the list can be scrolled if
requiredtoshowallvalues:
DHW1 Boiler 1
Tank temperature: 45.6ºC
3.8.6 Menu – DHW – Status – Real time
values – Outputs
Once outputs is selected the screen will
show the congured list of Domestic Hot
Watercircuits:
Outputs
DHW1 Boiler 1
Once a Domestic Hot Water circuit is
selected, then the following screen will
displaythecurrentRealtimevaluesforthe
conguredoutputs,onceagainitemsthatare
notconguredwillbeshownwithnovalue
butwith2dashestoindicatethis,thelistcan
bescrolledifrequiredtoshowallvalues:
DHW1 Boiler 1
DHW pump/valve: Off
3.8.7 Menu – DHW – Operating Mode
EachDomesticHotWatercircuitoperating
modecanbeset.Thiscontrolstheoperation
oftheselectedDomesticHotWatercircuit.
Operating mode
HC1 Boiler 1.1
HC2 Boiler 2.1
HC3 Boiler 2.2
Theoptionsare:
DHW Boiler 1
Standby
DHW Boiler 1
Time clock single day
DHW Boiler 1
Time clock multiple days
Standby–Frostprotectiononly
Timeclocksingleday–Normaloperation,timed
Timeclockmultipleday–Normaloperation,
timed.
3.8.8 Menu – DHW – Tank temperature
EachDomesticHotWatercircuittargettank
temperature can be set for different operating
modesfortheselectedDomesticHotWater
circuit.
Tank temperature
DHW1 Boiler 1
DHW1 Boiler 1
Tank temp day
Tank temp night
Tank temp holiday
Each selected tank temperature set point
canbeadjustedandthenset,theadjustment
screenisleftbypressingthebackbutton:
Tank temp day
65ºC
Tank temp night
10ºC
Tank temp holiday
10ºC
3.8.9 Menu – DHW – Settings
Each Domestic Hot Watercircuit has a
numberofsettingsthatcanbeadjustedfor
theselectedDHWcircuit.
Settings
HC1 Boiler 1.1
DHW1 Boiler 1
One time boost
Charge pump
Legionella
DHW1 Boiler 1
One time boost
Charge pump
Legionella
Frost protection
DHW1 Boiler 1
Charge pump
Legionella
Frost protection
Early start DHW storage
DHW1 Boiler 1
Legionella
Frost protection
Early start DHW storage
DHW1 Boiler 1
Frost protection
Early start DHW storage
3.8.10 Menu – DHW – Settings – One
time boost
Each DHW circuit can have a one-time
boost to allow for out of hours hot water
requirements.The boost can be enabled
andatanktemperaturesetforthisfunction.
On/Off
One time boost
On/Off
One time boost
Temperature
60ºC