ifm Operating Instructions IO-Link Master with EtherNet/IP interface StandardLine 8 Ports IP 65 / IP 67 (AL1122) 2017-05-31
Configuration
Name
Description
Possible values
Type compatible
V1.1 device with
Restore
IO-Link device is compatible with
the V1.1 IO-Link standard
Verification whether it is an
IO-Link device of the same type
(validation via vendor ID and
device ID)
The IO-Link master saves the
parameter values of the
connected IO-Link device once.
When connecting an IO-Link
device with factory settings, the
parameter values stored in the
IO-Link master are restored
automatically on the IO-Link
device.
[Port x IO-Link. Vendor ID]
ID of the manufacturer that is to be
validated
0 ... 65535
ID of the manufacturer of the IO-Link
device (ifm electronic: 310)
[Port x IO-Link. Device ID]
ID of the IO-Link device that is to
be validated
0 ... 16777215
ID of the IO-Link device
Store the changed values on the AL1122.