82
BS-98 1409 VER1 (U) (E)
5.1 Settings from the BS Menu
SD PM VIDEO PROCESS
SD PM VIDEO PROCESS sets the various SDTV PM video processes. (* option)
             ▲
 HDTV VIDEO PROCESS
 SDTV VIDEO PROCESS
 HD PM VIDEO PROCESS
 SD PM VIDEO PROCESS
 FUNCTION SETTING
 ENGINEER SET FILE RENEW
 PROGRAM UPDATE
             ▼
*** ENGINEER(2/2) ***
           
 CHAR LEVEL          120
 CHAR BG LEVEL       −36
SD PM VIDEO PROCESS
To position the ashing cursor on the "SD
PM VIDEO PROCESS", and determine.
The submenu "SD PM VIDEO PROCESS"
is displayed, on which you can perform
various settings.
Note:
SPRC module is an option.
Selecting this item becomes disabled when the SPRC module is not implemented.
Setting Item Set Value Description
CHAR LEVEL 0 to 200 Sets the character level of the SD PM OUT signals.
CHAR BG LEVEL -100 to 100 Sets the background level of characters on the SD PM OUT signals.

Table of Contents