84
BS-98 1409 VER1 (U) (E)
5.1 Settings from the BS Menu
ENGINEER SET FILE RENEW
The user registers and updates the memory (file) to back up the CCU/BS setting.
Note:
ENGINEER SET FILE
Up to three setting statuses of the equipment that the user customized can be saved in the internal memory. The data registered and
updated here can be invoked from "PRESET FILE LOAD" on the first page of MENU.
▲
HDTV VIDEO PROCESS
SDTV VIDEO PROCESS
HD PM VIDEO PROCESS
SD PM VIDEO PROCESS
FUNCTION SETTING
ENGINEER SET FILE RENEW
PROGRAM UPDATE
▼
*** ENGINEER(2/2) ***
FILE SELECT ENGINEER−1
DATA RENEW MODE
ENGINEER SET FILE RENEW
To position the flashing cursor on the
"ENGINEER SET FILE RENEW", and
determine.
The submenu "ENGINEER SET FILE
RENEW" is displayed, on which you can
perform various settings.
1 Set the blinking cursor to "FILE SELECT" and select a file to be created and updated.
Note:
The file is overwritten and updated.
2 Set the blinking cursor to "DATA RENEW MODE" and finalize.
At the lower section of the screen, "PUSH SET -> RENEW" is displayed.
When finalized, the target ENGINEER file is updated.
After writing the data, "COMPLETED" is displayed.