98
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Victrix Tera V2 24 Plus EU
Id
Parameter
Parameter Description Range Default
Customised
value
S0
DHW mini-
mum no. of fan
revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 = RPM)
27 (G20)
27 (G31)
S1
DHW maxi-
mum no. of fan
revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 = RPM)
118 (G20)
118 (G31)
S2
Ignition phase
no. of fan revs
Denes the operating speed of the fan during the ignition
phase
40 - 80
(x 50 = RPM)
44 (G20)
4 4 (G31)
Victrix Tera V2 35 Plus EU
Id
Parameter
Parameter Description Range Default
Customised
value
S0
DHW mini-
mum no. of fan
revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 = RPM)
27 (G20)
27 (G31)
S1
DHW maxi-
mum no. of fan
revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 = RPM)
120 (G20)
12 0 (G31)
S2
Ignition phase
no. of fan revs
Denes the operating speed of the fan during the ignition
phase
40 - 80
(x 50 = RPM)
56 (G20)
56 (G31)