Technical
data
TechDoku_CC1000_VCC1000_CC3000_VCC3000_GenPM_GB_86025010_86025110.doc
31
3 Technical data
(V)CC1000
(V)CC3000
Crucible diameter in mm
Crucible volume in cm³ (1)
1500
3400
Material weight
15 kg Ag, 22 kg Au 18 kt
30 kg Ag, 51 kg Au 18 kt
Max. Die Ø in mm
70
110
Outside dimensions die in
mm
120x30
160x40
Wire Ø in mm (1)
max. 40
max 5 x Ø 15 oder 1x 40
Sheet L x B in mm (1)
40x40 with round die or max.
100 x 10 with rectangular die
max. 130 x 12
Tube Ø in mm (1)
max.50
max. 50
Power in kW
20
30
Mains supply
3 x 400 V,50 or 60 Hz
Fuse protection A
32
44 (external 63)
Short circuit current
max. 5.0 kA
max. 10 kA
Thermocouple
Typ K (NiCr-Ni; max. 1200 °C) oder
Typ S (PtRh-Pt; max. 1500 °C) (with other insulations)
Cooling water supply
2 x Ø 13 mm, fittings with1/4” thread (Øa 13.2 mm)
2.5 - 5 bar, min. 400 l/h, max. 6 °dH
water filter for suspended particles
Cooling water recoil
pressureless
Cooling water entry tem-
perature in °C
15 25
Ambient temperature in °C
10 35
Relative atmospheric hu-
midity
20 - 80 %
Protective gas supply
1 x Ø 6 mm, fittings with ¼“ thread (Øa 13.2 mm)
max. 8 bar, pure N
2
, pure Ar (at least 99,9 % purity) or forming gas
90/10, estimated consumption 4-6 l/min
Vacuum supply (VCC)
1x Ø 13 mm, fittings with ¼thread (Øa 13.2 mm),
0-20 mbar absolute, at least 21 m³/h
Weight in kg
220
280
Dimensions in mm
(width x depth x height)
700 x 1000 x 1870
800 x 1100 x 2000
Maximum melting temper-
ature in °C
1500 (with special insulations)
Options
Granulating tank
Cutting device
Sheet- and wire dies
Noise emission
75 dB (A)
(1) optional changing

Table of Contents