The machine may be opened only by an expert.
Disturbance
Reason
Machine can’t be
switched on.
Mains voltage missing.
Heating don’t work.
Cooling water supply not switched on („E010”).
Protective gas supply not switched on („E013“).
Thermocouple not put in or faulty („0FbE“).
Generator overheated (too hot, „E021“).
Another error („Exxx“).
Temperature indication
not right.
Wrong thermocouple adjusted, see annexe.
Thermocouple faulty („E041“).
Because of this the generator can switch off!
Low generator output
Set value of temperature regulator too low.
If you have additional error messages Exxx, then please see last
pages of software documentation in annexe. Or you search in our
Webshop. You’ll find error document typing in the ‚Exxx‘-number.
Please replace W with E for search.
7.9 Service
If you need technical support from company INDUTHERM, we’d like
to have following information of your machine at first contact:
Service No. M17999 PM below mains switch or
Serial number from identification plate at machine backside.
Parameter printout. Please press button “Printer” at front panel
for 5 seconds incessantly.