trapulsPac - User Guide
Chapter 3 – Reference
Sub Index 2
Description Motor temperature warning threshold
Data Type Unsigned32
Access rw
PDO Mapping No
Unit (ohm)
Default value 2400
This parameter defines the threshold of the equivalent resistor corresponding to the temperature at which a
warning will be notified.
Sub Index 3
Description Motor temperature error threshold
Data Type Unsigned32
Access rw
PDO Mapping No
Unit (ohm)
Default value 2400
This parameter defines the threshold of the equivalent resistor corresponding to the temperature at which an error
will be triggered.
Inde
x
0x3323
Name Motor temperature probe monitoring
Object Code VAR
Data Type Unsigned32
Object Class all
Access ro
Unit (ohm)
PDO Mapping No
The returned value gives an image of the equivalent resistance (in ).
3.2.2.6 - IGBT temperature
IGBT module temperature value
Index 0x3328
Name IGBT module temperature information
Object Code VAR
Data Type Integer 16
Object Class all
Access ro
PDO Mapping Yes
Unit °C
Remark Only valid for the 400 V range

Table of Contents

Other manuals for Infranor XtrapulsGem

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infranor XtrapulsGem and is the answer not in the manual?

Infranor XtrapulsGem Specifications

General IconGeneral
BrandInfranor
ModelXtrapulsGem
CategoryController
LanguageEnglish

Related product manuals