MD320/MD320N User Manual Function Parameter Table
73
Function
code
Name LED display Set range
Minim-
um unit
Factory
default
value
Modication
description
F3-00
V/F curve
setup
V/F curve setup
0: Straight V/F curve
1: Multiple-point V/F curve
2: Square V/F curve
1 0
F3-01 Torque boost Torque boost 0.0: (automatic)0.1% to 30.0% 0.1% 1.0%
F3-02
Cutoff
frequency of
torque boost
frequency of
torque boost
0.00 ~ maximum frequency 0.01Hz 50.00Hz
F3-03
V/F frequency
point 1
V/F frequency
1
0.00Hz ~ rated motor frequency 0.01Hz 0.00Hz
F3-04
V/F voltage
point 1
V/F voltage 1 0.0%
100.0% 0.1% 0.0%
F3-05
V/F frequency
point 2
V/F frequency 2 0.00Hz ~ rated motor frequency 0.01Hz 0.00Hz
F3-06
V/F voltage
point 2
V/F voltage 2 0.0%
100.0% 0.1% 0.0%
F3-07
V/F frequency
point 3
V/F frequency 3 0.00Hz ~ rated motor frequency 0.01Hz 0.00Hz
F3-08
V/F voltage
point 3
V/F voltage 3 0.0%
100.0% 0.1% 0.0%
F3-09
Slip
compensation
coefcient
Slip
compensation
coefcient
0.0%
200.0% 0.1% 0.0%
F3-10 AVR selection AVR selection
0:Iinactive
1: Active
2:Inactive only at speed-down
time
1 2
F3-11
Oscillation
suppression
gain
Oscillation
suppression
gain
0
100 1
Model
dependent
F4 Input terminal