3 Electrical Installation
- 68 -
Table 3-6 Main circuit cable selection for MD880-01S-0048-4-B/MD880-01S-0060-4-B
AC Drive
Model
Rated
Current
(A)
Recommended
Input/Output
Power Cable
(mm
2
)
Recommended
Lug Model
Recommended
Grounding
Cable (mm
2
)
Recommended
Grounding
Cable Lug Model
Tightening
Torque
(N·m)
MD880-01S-
0048-4-B
48 3 x 10 GTNR16-6 10 GTNR10-6 4.0
MD880-01S-
0060-4-B
60 3 x 16 GTNR16-6 16 GTNR16-6 4.0
345678
108&3 .0503
#3
.
4&.4TDSFXT
Figure 3-28 MD880-01S-0078-4-B/MD880-01S-0094-4-B
Table 3-7 Main circuit cable selection for MD880-01S-0078-4-B/MD880-01S-0094-4-B
AC Drive
Model
Rated
Current
(A)
Recommended
Input/Output
Power Cable
(mm
2
)
Recommended
Lug Model
Recommended
Grounding
Cable (mm
2
)
Recommended
Grounding
Cable Lug
Model
Tightening
Torque
(N·m)
MD880-01S-
0078-4-B
78 3 x 16 GTNR16-6 16 GTNR16-6 4.0
MD880-01S-
0094-4-B
94 3 x 16 GTNR16-6 16 GTNR16-6 4.0
3 4
108&3
5
#3
7
6
8
.0503
.珞BUXBTIFS
TQSJOHXBTIFS
OVU
.4&.4
TDSFX
Figure 3-29 MD880-01S-0116-4-B/MD880-01S-0149-4-B