LP600 Users Manual
Rev E, February 2017
Page 20 of 43
Mode Menu
Mode Menu
To access the mode menu simultaneously press the PRINT/ACCUMULATE and ZERO
buttons. The display will show “.”. If it doesn’t, go to Calibration Enable Jumper
section and verify the scale is in the RUN position. (shorting pins 2 and 3(RUN)
At times it will be necessary to enter up to a five digit number. When this is necessary
the current number will be displayed with the right most digit flashing. The flashing digit
may be incremented by pressing the LOCAL/TOTAL button. To move one digit to the
left, press the ZERO key. When you have finished entering a number press the PRINT/
ACCUMULATE button. The settings are saved once PRINT/ACCUMLATE is pressed to
advance the menu, and the scale can then be turned off.
Step
Function
Note
Default
.
Backlight
, , 


Set Point 1
0 to 199999


Set Point 2
0 to 199999

.
Firmware Version
View only
XXXXX
. 
Average rate
1 to 120

.
Average threshold
1 to 10000


Auto off
000 = off, 1 to 240


Print Mode
0 = On-demand, 1 = Continuous,
2 = Accumulating Total Axle,
3 = Accumulating Total Standard


Printer baud rate
1200, 2400, 4800, 9600, 19200,
or 38400, 57600, 115200


Measurement units
lb or kg
lb

Protocol
, , ., or 

.
Interface baud rate
9600 or 115200


Radio Enable
Yes or no


Radio Channel
01 to 12

.
Radio Network ID
0 to 65534

.
Radio Encryption Key
1 to 65534

.
Restore Radio Defaults
0 or 3
