13.The display will show “”. Press the PRINT/ACCUMULATE button. The
display will show the current setting flashing. This is the radio enable status and is
either on or off. Use the LOCAL/TOTAL button or the ZERO button to toggle
between the settings. When the desired status is flashing, press the PRINT/
ACCUMULATE button. If you select “no” the scale will skip the rest of the settings
and return to normal weighing.
14.The display will show “”. Press the PRINT/ACCUMULATE button. The
flashing digit shows the current setting. All scales in a system must be set to the
same radio channel setting in order to communicate with each other. Use the
LOCAL/TOTAL button to increment and the ZERO button to move the number
flashing to the left. When the display shows the desired number, press the
PRINT/ACCUMULATE button.
15.The display will show “.”. Press the PRINT/ACCUMULATE button. The
display will show the current setting with the number on the right flashing. All scales
in a system must be set to the same Personal Area Network ID setting in order to
communicate with each other. Use the LOCAL/TOTAL button to increment and the
ZERO button to move the number flashing to the left. When the display shows the
desired number, press the PRINT/ACCUMULATE button.
16.The display will show “”. Press the PRINT/ACCUMULATE button. The
display will show “” with the number on the right flashing. Use the
LOCAL/TOTAL button to increment and the ZERO button to move the number
flashing to the left. Enter any number from 1 to 65534 to enter an encryption key, or
enter 0 to leave the current encryption key unchanged. For security purposes, this
setting is not accessible to view and will always show as “”. All scales in a
system must be set to the same encryption key setting in order to communicate with
each other. When the desired encryption key is displayed, press the PRINT/
ACCUMULATE button.
17.The display will show “.”. Press the PRINT/ACCUMULATE button. The
display will show “” with the number flashing. Use the LOCAL/TOTAL button to
increment and the ZERO button to decrement the number. Setting the number to 3
will restore the default radio settings. All other numbers will have no affect on the
radio set-up. When the desired number is flashing, press the PRINT/
ACCUMULATE button. The scale will return to normal weighing.
If the scale does not have the radio option installed, the “”, “”, “
and the Encryption key will be view only.