Chapter 4 — Configuration Command Reference
54 SR61 Cordless Scanner User’s Guide
Trigger Timeout
SR61xV (linear imager) and SR61xA (area imager) only. Sets the
trigger timeout for the Trigger Mode command. You can set
trigger timeout from 1 to 4095 seconds.
Turn Off After Good Read
Sets how the SR61 operates in level and pulse trigger modes.
UPC/EAN
Enables or disables decoding of Universal Product Code (UPC)/
European Article Numbering (EAN) symbology. UPC/EAN are
fixed-length, numeric, continuous symbologies that use four
element widths. A scanner that is configured to decode EAN bar
codes can decode UPC, but the reverse is not true. UPC code is a
subset of EAN code.
ISBN
ISBN (International Standard Book Number) is a 10-digit
symbology that uniquely identifies books for tracking and
ordering.
With ISBN enabled, the first three characters (978) are ignored,
and the checksum is calculated on the remaining characters.
GTIN Processing
With GTIN (Global Trade Item Number) processing enabled,
two zeros are padded to the beginning of UPC-A, and one zero is
padded to the beginning of EAN-13 to expand the numbers to
14 digits. To use GTIN processing you also need to enable the
corresponding UPC/EAN symbology.
Trigger
Mode
Turn Off After
Good Read
SR61 Behavior
Level Enabled The SR61 turns off after it successfully
reads a bar code.
Level Disabled The SR61 stays on until you release the
Scan button.
Pulse Enabled The SR61 turns off after it successfully
reads a bar code.
Pulse Disabled The SR61 stays on until the Trigger
Timeout period is reached.