Goodrive35 inverters Function codes
138
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
3 for the
iron core of
AM2
P12.14
Magnetic
saturation
coefficient
4 for the
iron core of
AM2
0.0~100.0%
40.0%
P12.15
Rated
power of
synchrono
us motor 2
0.1~3000.0kW
Set the parameter of
the controlled
asynchronous motor.
In order to ensure the
controlling
performance, set the
P12.151~P12.19
according to the name
plate of the
asynchronous motor.
Goodrive35 series
inverters provide the
function of parameter
autotuning. Correct
parameter autotuning
comes from the
correct setting of the
motor name plate.
In order to ensure the
controlling
performance, please
configure the motor
according to the
Depend
on
model
P12.16
Rated
frequency
of
synchrono
us motor 2
0.01Hz~P00.03
(the Max. frequency)
50.00
Hz
P12.17
Number of
poles pairs
for
synchrono
us motor 2
1~128
2
P12.18
Rated
voltage of
synchrono
us motor 2
0~1200V
Depend
on
model
P12.19
Rated
current of
synchrono
us motor 2
0.8~6000.0A
Depend
on
model
P12.20
Stator
0.001~65.535Ω
Depend
www.barghmaher.ir