Goodrive35 inverters Maintenance and hardware diagnostics
263
Rotation
direction
Wind
direction
Wind
direction
Fan maintenance diagram for machine2.2kW
Rotation
direction
Wind
direction
Wind
direction
Fan maintenance diagram for machine4kW
6. Connect the power supply.
9.4 Capacitorss
9.4.1 Capacitors reforming
The DC bus capacitors must be reformed according to the operation instruction if the
inverter has been stored for a long time. The storing time is counted form the producing date
other than the delivery data which has been marked in the serial number of the inverter.
Time
Operational principle
Storing time less than 1
year
Operation without charging
Storing time 1-2 years
Connect with the power for 1 hour before first ON command
Storing time 2-3 years
Use power surge to charge for the inverter
charging 25% rated voltage for 30 minutes
charging 50% rated voltage for 30 minutes