Goodrive35 inverters Maintenance and hardware diagnostics
263
Rotation
direction
Wind
direction
Wind
direction
Fan maintenance diagram for machine≤2.2kW
Rotation
direction
Wind
direction
Wind
direction
Fan maintenance diagram for machine≥4kW
6. Connect the power supply.
9.4 Capacitorss
9.4.1 Capacitors reforming
The DC bus capacitors must be reformed according to the operation instruction if the
inverter has been stored for a long time. The storing time is counted form the producing date
other than the delivery data which has been marked in the serial number of the inverter.
Storing time less than 1
year
Operation without charging
Connect with the power for 1 hour before first ON command
Use power surge to charge for the inverter
• charging 25% rated voltage for 30 minutes