Detailed instruction of parameters
Vibration control factor at
low frequency of motor 2
Vibration control factor at
high frequency of motor 2
Vibration control threshold
of motor 2
0.00Hz~P00.03 (the Max. frequency)
0: No action
1: Automatic energy-saving running
0: Keypad: the output voltage is
determined by P04.28.
1:AI1;
2:AI2;
3:AI3;
4:HDI1;
5:Multi-step speed;
6:PID;
7:MODBUS communication;
8:PROFIBUS/CANopen communication;
9:Ethernet communication;
10: Reserved
0.0%~100.0%
(the rated voltage of motor)
P04.32~100.0%(the rated voltage of
motor)
0.0%~P04.31(the rated voltage of motor)
7.5 Torque control
Goodrive35 series inverters support two kinds of control mode: torque control and rotation speed
control. The core of rotation speed is that the whole control focuses on the stable speed and
ensures the setting speed is the same as the actual running speed. The Max. Load should be in
the range of the torque limit. The core of torque control is that the whole control focus on the stable