Goodrive35 inverters Basic operation instruction
243
placement is too small, the positioning deceleration time is invalid and it will enter into the direct
deceleration mode.
(6) Positioning operation
The motor will keep on the current position after positioning. Set group P05. If the terminal receives
the enabling signal, the motor will operate at the setting speed in speed mode, after receiving
photoelectric switch signal, it will position again.
(7) Position retention
During the positioning, the position loop gain is P21.03, but after positioning, it is P21.02. Adjust
P03.00, P03.01, P20.05 and P21.02 to keep the position and avoid vibration.
7.17 Fault solutions
Goodrive35 series inverters provide sufficient fault procedure information for the convenience of
users application.
In running
Fault occurs and the
keypad displays the
fault code
Look up the fault
reason according
to the fault code
According to
P07.33~P07.40 to
estimate the best reason
Rerunning
Normal running
Settle the fault
consult INVT
Y
N
N
Y
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P07.27
Current fault type
0:No fault
1:IGBT U phase protection(OUt1)
2:IGBT V phase protection(OUt2)
0
P07.28
Previous fault type
P07.29
Previous 2 fault type
P07.30
Previous 3 fault type