Goodrive35 inverters Basic operation instruction
202
Current
reference
channel
P00.09
Multi-function terminal
function 13
Switch from A channel
to B channel
Multi-function
terminal function
14
Switch from
combination
setting to A
channel
Multi-function
terminal function
15
Switch from
combination
setting to B
channel
A
B
/
/
B
/
/
/
A+B
/
A
B
A-B
/
A
B
Max(A,B)
/
A
B
Min(A,B)
/
A
B
Note: "/" means the multi-function terminal is invalid under the current given channel.
When select multi-function terminal UP (10) and DOWN (11) to set the internal assistant frequency,
P08.44 and P08.45 can be set to increase or decrease the set frequency quickly.
Sx
Sy
Up terminal function selection=10
DOWN terminal function
selection=11
UP terminal state
DOWN terminal state
T
F
T
T
UP terminal frequency increasing integral rate P08.44
DOWNterminal frequency increasing integral rate P08.45
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.03
Max. output frequency
P00.04~400.00Hz
50.00Hz
P00.04
Upper limit of the running
frequency
P00.05~P00.03
50.00Hz
P00.05
Lower limit of the running
frequency
0.00Hz~P00.04
0.00Hz
P00.06
A frequency command
0:Keypad
1: AI1
2: AI2
0
P00.07
B frequency command
2
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals