EasyManua.ls Logo

INVT Goodrive270 Series

INVT Goodrive270 Series
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive270 series VFD for fan and pump Function parameter list
-249-
Function
code
Name
Description
Default
Modify
7: m/min
8: m/h
9: m
3
/s
10: m
3
/min
11: m
3
/h
12: kg/s
13: kg/min
14: kg/h
1521: Reserved
P90.01
Number of decimal
places
03
2
P90.02
PID1 given max.
value
0.0030.00
It is displayed with two decimal places by
default. If P90.01 is changed, the number of
decimal places changes.
10.00
P90.03
PID1 reference
upper limit
P90.04P90.02
10.00
P90.04
PID1 reference
lower limit
0.00P90.03
0.00
P90.05
ACC/DEC time of
PID1 reference
value
0.01000.0s
0.0s
P90.06
PID1 reference
source 1
0: Keypad (P90.07)
1: AI1
2: AI2
3: AI3
4: HDIA
5: Reserved
6: Communication card
0
P90.07
PID1 reference
value 1 through
keypad
P90.04P90.03
0.100
P90.08
PID1 feedback
source 1
0: Keypad (P90.09)
1: AI1
2: AI2
3: AI3
4: HDIA
5: Reserved
0

Table of Contents

Related product manuals