Goodrive270 series VFD for fan and pump Function parameter list
-253-
Function
code
Name
Description
Default
Modify
6: m/s
7: m/min
8: m/h
9: m
3
/s
10: m
3
/min
11: m
3
/h
12: kg/s
13: kg/min
14: kg/h
1521: Reserved
P91.01
Number of decimal
places
03
2
P91.02
PID2 given max.
value
0.0030.00
It is displayed with two decimal places by
default. If P91.01 is changed, the number of
decimal places changes.
10.00
P91.03
PID2 reference
upper limit
P91.04P91.02
10.00
P91.04
PID2 reference
lower limit
0.000P91.03
0
P91.05
ACC/DEC time of
PID2 reference
value
0.01000.0s
0.0s
P91.06
PID2 reference
source 1
0: Keypad (P91.07)
1: AI1
2: AI2
3: AI3
4: HDIA
5: Reserved
6: Communication card
0
P91.07
PID2 reference
value 1 through
keypad
P91.04P91.03
0.100
P91.08
PID2 feedback
source 1
0: Keypad (P91.09)
1: AI1
2: AI2
3: AI3
0