EasyManua.ls Logo

ISE Sonos - Page 32

ISE Sonos
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ise smart connect KNX Sonos
Configuration
Order No. 1-0001-002
Product Manual Page 32 (76)
Object
Name
Direction
Data width
DP type
Flags
(CRWTU)
4 (group 1)
104 (group 2)
204 (group 3)
304 (group 4)
404 (group 5)
Play state
Read
1 bit
1.010
CR-T-
Rubric:
Playback
Data type:
Start/Stop
Function:
Group 1/2/3/4/5 Indicates whether music is playing, or whether it is paused or
stopped
Description:
1 = Playback in progress, 0 = No playback active
Object
Name
Direction
Data width
DP type
Flags
(CRWTU)
5 (group 1)
105 (group 2)
205 (group 3)
305 (group 4)
405 (group 5)
Pause state
Read
1 bit
1.003
CR-T-
Rubric:
Playback
Data type:
Enable
Function:
Group 1/2/3/4/5 Indicates whether music is plaused, or whether it is playing
or stopped
Description:
1 = Playback paused, 0 = Playback in progress or stopped
Object
Name
Direction
Data width
DP type
Flags
(CRWTU)
6 (group 1)
106 (group 2)
206 (group 3)
306 (group 4)
406 (group 5)
Stop state
Read
1 bit
1.010
CR-T-
Rubric:
Playback
Data type:
Start/Stop
Function:
Group 1/2/3/4/5 Indicates whether music is stopped, or whether it is playing
or paused
Description:
1 = Playback stopped, 0 = Playback in progress or paused
Object
Name
Direction
Data width
DP type
Flags
(CRWTU)
7 (group 1)
107 (group 2)
207 (group 3)
307 (group 4)
407 (group 5)
Volume control
Write
1 byte
5.001
C-W--
Rubric:
Volume
Data type:
Percent (0 to 100%)
Function:
Group 1/2/3/4/5 Set volume (absolute)
Description:
Enables setting of the volume over the bus: 0 corresponds to 0%, and 255 to
100% volume

Table of Contents