Technical Specification
Parameter IT-M7722D
Max. output voltage
±400Vdc
Maximum output current (rms)
±3A
DC voltage Accuracy ±(0.2%+0.2% F.S.)
Dynamic response time (Full load of
10~90%)
≤0.5ms
Meter
AC Voltage
Range
0~300V
Resolution 0.1V
Accuracy ±(0.25%+0.25% F.S.)
AC current *4 (Rms,
High range)
Range
0.1~3A
Resolution 10mA
Accuracy ±(0.5%+0.5% F.S.)
AC current (rms, low
range at 100HZ)
Range
0.1~1250 mA
Resolution 0.1mA
Accuracy ±(0.25%+0.25% F.S.)
AC current (peak)
Range
0~4.25A
Resolution 10mA
Accuracy ±(0.4%+0.8% F.S.)
DC voltage Accuracy ±(0.25%+0.25% F.S.)
DC current (High
range)
Accuracy ±(0.25%+0.355% F.S.)
DC current (Low
range)
Accuracy ±(0.25%+0.355% F.S.)
Frequency
Range
45~1000Hz
Resolution *5 0.1Hz
Accuracy *2
±0.1%
Power *4 (S)
Resolution 100mVA
Accuracy ±(0.5%+0.5% F.S.)
Other
Protection
OTP, OCP, OVP, OPP
Copyright © Itech Electronic Co., Ltd.