Technical Specification
Parameter IT-M7722L
AC current (peak)
Range
0~8.5A
Resolution 10mA
Accuracy ±(0.4%+0.8% F.S.)
DC voltage Accuracy ±(0.25%+0.25% F.S.)
DC current
Accuracy ±(0.25%+0.355% F.S.)
Frequency
Range
45~100Hz
Resolution *4 0.1Hz
Accuracy *2
±0.1%
Power (S)
Resolution 100mVA
Accuracy ±(0.5%+0.5% F.S.)
Other
Protection
OTP, OCP, OVP, OPP
Dimension
(WxHxD)
Without foot post,
protective cover
215 × 44.45 × 450 mm
With foot post, pro-
tective cover
234 × 57.02 × 500 mm
Weight
5 KG
*1: Min voltage for THD test is 100Vac.
*2: Min voltage for frequency display accuracy is 100Vac.
*3: Tested with pure resistive load.
*4: The applicable range of frequency resolution is 45~99.9Hz.
7.7 IT-M7723
Parameter IT-M7723
AC Input
Voltage
100–240Vac
Phase
Single-phase
Frequency
47-63Hz
Max.current 18A
Power factor
0.99 (Typical)
AC Output
Copyright © Itech Electronic Co., Ltd.