46
ALS 4.0 XE
PRODUCT MANUAL
EN
Figure 115
Step 7 – Select “Execute L1 Calibration”. This button is
shown in Figure 115 and Figure 116.
Figure 116
The following message (Figure 117) should appear.
Figure 117
Step 8 – Repeat for axis L2.
Step 9 – Select “Exit”.
Step 4 – To calibrate L1/L2, select “Controller” from the
task bar at the bottom of the screen (Figure 112).
Figure 112
The screen in Figure 113 will appear:
Figure 113
Step 5 – Select the “Calibrate L1 & L2 & L1P Lengths”
button (circled on Figure 113 and shown in Figure 114).
Figure 114
Step 6 – Enter the commanded distance (the length
input) and the actual measured distance using the box
shown in Figure 115.