Delayed A confirmed
Intrusion alarm with an entry and exit delay, timer A - see the chapter 8.4.3
Confirmed intrusion reaction.
Repeated instant Instant intrusion alarm – see the chapter 8.4.3 Repeated reaction below.
Repeated delayed A
Intrusion alarm with an entry and exit delay, timer A – see the chapter 8.4.3
Repeated reaction below.
Tampering
Tamper alarm any time (the section does not need to be set).
24 hours
Immediate intrusion alarm (the section does not need to be set).
Silent Panic
Silent Panic alarm:
1) EW and IW not activated (see chapter 8.5 Types of alarms);
2) the keypad does not beep although otherwise it is set like this;
3) if the system can distinguish who triggered the Panic alarm (e.g. through a tag
with adopted user’s identity or reverse entering of the code by the user, it does not
send Panic SMS to this user. Devices with the Silent Panic reaction cannot be
disabled by the Disabled option.
Audible Panic
Audible panic alarm (the behaviour is the same as a Silent panic, the only
difference is that an alarm is signalled by the used siren according to the table
in chapter 8.5 Types of alarms).
Fire alarm
Fire alarm any time (the section does not need to be set).
Fire confirmation
Fire alarm any time (the section does not need to be set), see the chapter 8.4.3
Confirmed fire reaction below.
Fire instant
Fire alarm only if the respective section is set
Gas
A fire alarm triggered by a gas leakage detector can be always triggered
regardless of the state of the section (combustible or CO)
Health troubles
Sends a health trouble report
Flooding
Sends a flood alarm
Set / Partial Set
(e.g. for JA-182J,
186J, 188J)
Setting (partial setting) of a section. If the section is a common one, all sections
that belong to it will be set at the same time. This reaction also has the Unset
function.
Mute
Silencing of the internal siren with a subsequent report of the presence of a person
in the building.
Report A / B / C / D
A special report is sent (special reports A, B, C and D are set in the Reports
to Users tab), which may be accompanied by a voice message call. If saving
of special reports in the event history is enabled, reports are also sent to the ARC.
Key-Box
A special reaction designed for sealed key in case of emergency, etc the opening
of which will send a report to the ARC without activating the alarm with a siren.
Instant always
Instant zone reaction. If set, then based on activation, instant including EW and IW
alarm warnings is activated also during exit delay time.
None
Without any impact for intrusion alarm; however, the device may be used
to activate PG outputs.
None with no tamper
The system reacts to detector triggering by PG output control only. None of
the alarm types are triggered (even a tamper alarm), fault detection is kept.
8.4.3 Limitation of false alarms
In installations with an increased risk of false alarms special reaction types can be used:
Confirmed intrusion reaction – if in a set section a detector with confirmed reaction is activated, the system
only reports an unconfirmed alarm to the ARC and waits for confirmation by another detector. The alarm
may be confirmed by any intrusion detector in a set section. In the Parameters tab you can define whether
the confirmation can come from any set section or it must be from the same section. You can also set the time
for which the system waits for confirmation by another detector in the Parameters tab (up to 60 min). If the alarm
is not confirmed within the pre-determined period of time, no alarm is released. If a confirmed delayed reaction
is set, activation of a detector only initiates sending of an unconfirmed alarm after expiration of the entry delay.
Confirmed reaction can only be used if a higher number of intrusion detectors are installed in the building
(to enable confirming).