Always set
immediately
It sets pre-set section(s) immediately without an exit delay or any acoustic indication.
The system is set immediately so no movement is possible in the protected premises.
The option is for fast and silent setting with no warning. The control panel doesn´t fully
respect all ways of setting and checking the systems ready to be set rules.
Always set
partially and
immediately
It sets pre-set section(s) partially and immediately without an exit delay or any acoustic
indication. The system is set immediately in a pre-set time. The option is for fast and silent
setting with no warning. The control panel doesn´t fully respect all ways of setting and
checking the systems ready to be set rules.
Unset
Unset pre-set section from any guarding level (fully or partially set).
No
No control function pre-set.
PG output control options using calendar:
Activate PG
Activates programmable output(s) if they are not blocked (for instance by calendar, device
or section).
Deactivate PG
Disable programmable PG outputs.
Block PG
Blocks pre-set PG outputs. Those outputs won´t be possible to switch on at all until it will
be unblocked by the calendar action Unblock PG“. Entering or leaving service mode
don´t unblock it.
Unblock PG
Unblocks pre-set PG output blocking.
No
No blocking function pre-set.
Function blocking action by the calendar:
Every planned action can be blocked by one optional PG output. Blocking means: when a PG output is
activated then a specific action won´t be performed for a predefined time. This blocking can for example be a
blocked calendar action for unsetting before you go for a holiday. Blocking can be indicated on a control
segment on the keypad (pre-set to PG ON / OFF) named as “Holiday”, etc.
9.5 System control via communicator voice menu (GSM / PSTN)
The security system can be controlled remotely thanks to the implemented voice menu and DTMF tones
on the caller’s cell phone. By calling from a previously known SIM card telephone number or a land line
telephone number the system picks up the call after a pre-set number of rings (default is 3 rings), the control
panel plays an introduction voice message and according to the settings maybe require a valid code entry.
The caller has to authorize himself by his access code. When the code is successfully verified then the system
tells you the status of the whole system and according to caller authorization offers other control options.
The parameter “No code for voice menu and SMS” in the Communication tab the user can be authorized
according to a pre-set telephone number stored in the Users list and then the code doesn´t have to be required.
The status of a section can be controlled via the voice menu, entering and leaving service mode and recording
voice messages with the names of individual sections and special reports. Control of PG outputs is not possible
via the voice menu.
Caution: Makes sure nobody is present in the protected premises before you set the system remotely.