EasyManua.ls Logo

jablotron JA-101K - Overview Table of Groups of Events Reported to Users

jablotron JA-101K
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
||
|
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels 53 / 110 MLJ51410
9.13 Overview table of Groups of Events reported to users
All events which are sent to users (35) are assigned to 5 basic groups. Every single group can be assigned to
users arbitrary. Users to whom a group will be assigned will be sent reports from this group. When the basic
settings of the groups are not enough then there are two special groups which can be used. User defined group
1 and 2. Events can be added to those groups and can be given to only specific users.
Overview table:
Order Event Group
1 Setting
SMS about Setting / Unsetting (3)
2 Unsetting SMS about Setting / Unsetting (3)
3 Partially setting
SMS about Setting / Unsetting (3)
4 30 minute mains fault SMS alerts (1) / Alarm call (2)
5 Mains restored after 30 min SMS alerts (1) / Alarm call (2)
6 Instant alarm SMS alerts (1) / Alarm call (2)
7 Instant alarm cancelled SMS alerts (1) / Alarm call (2)
8
Delay alarm
SMS alerts (1) / Alarm call (2)
9 Delay alarm cancelled SMS alerts (1) / Alarm call (2)
10
Tamper alarm
SMS alerts (1) / Alarm call (2)
11 Tamper alarm cancelled SMS alerts (1) / Alarm call (2)
12 Fire alarm
SMS alerts (1) / Alarm call (2)
13 Fire alarm cancelled SMS alerts (1) / Alarm call (2)
14 Panic alarm
SMS alerts (1) / Alarm call (2)
15 Panic alarm cancelled SMS alerts (1) / Alarm call (2)
16 Health troubles
SMS alerts (1) / Alarm call (2)
17 Flooding SMS alerts (1) / Alarm call (2)
18 Code breaking attempt SMS alerts (1) / Alarm call (2)
19
Set with active zone (when confirmation enabled)
SMS alerts (1) / Alarm call (2)
20 Section without movement SMS alerts (1) / Alarm call (2)
21
System start (out of service mode)
Fault and service SMS (5)
22 Device low battery Fault and service SMS (5)
23
Device battery OK
Fault and service SMS (5)
24 Fault (device, communicator) Fault and service SMS (5)
25 Fault end
Fault and service SMS (5)
26 Service mode entry Fault and service SMS (5)
27 Service mode left
Fault and service SMS (5)
28 Low BATTERY Fault and service SMS (5)
29 BATTERY OK Fault and service SMS (5)
30 ARC communication fault Fault and service SMS (5)
31 ARC communication restored Fault and service SMS (5)
32
RF jamming
Fault and service SMS (5)
33 RF jamming end Fault and service SMS (5)
34
Low credit balance
Fault and service SMS (5)
35 Alarm photo Photo (4)
The assignment of events distinguished by the system to groups is specified in the table. On occurrence of an
event the system generates an SMS in the format:
Installation name (see the Initial setup tab):
Time (of event occurrence), Event (see table).
Event source (see the Device/Name or User/Name tab), Section (where the event occurred); (in case of
more events they are arranged one after another in one message separated with semicolons);
Time (time and date of sending)
Example of a sent SMS:
JABLOTRON 100 (installation name)
17:01:10, Delayed alarm (event time, event)
Door magnet, Ground floor (detector name, section name)
17:01:25, Instant alarm (event time, event)
Staircase movement, Upstairs (detector name, section name)
Time 17:01 22.7. (time of sending)

Table of Contents