Activation: by entering a special activation code you can add a language (languages) to the choice
of languages that is (are) released for the country the control panel is designed for.
Notes:
If one of the default languages (EN/CZ) is required, the Activate function will not be used.
If you request another language, after entering the activation code you can select one of the available
languages from the Language menu.
Also you will need to upgrade the firmware of the wireless components (specifically access modules with
display to get selected language into them, too).
Initial setup tab description:
Codes with a prefix – this function determines the ways of entering all access codes for user authorization.
When the function is enabled the system requires a 1 or 3 digit prefix (position of the code) ended by a * symbol
before an access code entry. It allows users to change their own codes from the keypad. However, to be able
to control the system, you must use a code with the sequential number of the code (prefix). If this parameter
is disabled, only a 4 digit access code is required to be entered and the codes may only be changed
by the system Administrator, who will assign codes and will be the only person authorized to change user rights
(thus he/she will have a knowledge of them). The administrator is also responsible for avoiding code duplicity.
Warning: Anytime this parameter is disabled, it will irreversibly delete all the user codes and settings
of the Service Code and Administrator Code and restore the default values. Users’ authorizations and the RFID
card / tags of already existing users are not changed.
Enable 125kHz EM UNIQUE card standard - If disabled, the identification RFID cards / tags
(JA-190J, JA-191J, JA-192J, JA-194J) recommended by a manufacturer may only be used. If enabled, cards of
other manufacturers working with the above mentioned frequency are also allowed.
Code length – to increase the alarm system security level during authorization it is possible to pre-set the
user code length regardless of the prefix function. There can be 4,6 or 8-digit codes. When the code length
is changed then Service and Administrator codes are set to the default values and earlier pre-set codes
are erased.