Security System Control Panels 77 / 110 MLJ51410
Siren IW when partially set
Allows you to set an acoustic alarm with the IW system if the section is partially
set. Fire and 24 hours reactions never activate a siren in the case of an alarm,
regardless of how is this parameter set.
Sirens enabled*
Enables all BUS and wireless sirens of the system (designed for disabling
the acoustic alarm during system testing)
Warning about default
codes*
On completion of service an SMS message is sent to the service technician
on position 0 that default codes have been left in the system.
Administrator restricted
Service and ARC
It blocks independent access of service technicians and ARC to the system.
Note: In case of remote access of a technician to the system via F-Link
the administrator may get authorized using a keypad in the building. In case
of local connection of a technician to the control panel using a USB cable
the administrator may get authorized remotely using the voice menu.
Service and ARC control
system*
This setting allows the service technician and ARC technician to control
the system for all the sections. If this parameter is disabled, the technician
is not authorized to control sections and will only be able to enter the Service
mode after unsetting of all the sections by the Administrator or a user.
Trial operation
All alarms are limited to 60 sec. and reported by means of SMS to defined
users and the service technician (position 0) although alarm reports
are not activated for him. Test operation is automatically terminated after 7 days
from leaving the Service mode. During the test mode siren alarms set to EW
(external warning) are disabled.
Service required
If this function is on, 12 months after the last closing of Service mode it initiates
the “System requires service check” event in the system, which is, together with
the Information icon, displayed on keypads with an LCD screen and registered
in the event history. After pressing the “i” key the text “call the service
technician” will be displayed together with his phone number. The message
on LCD disappears automatically when the service technician locally
accesses the system. The annual check counter performs a reset.
Duress access control
Serves for triggering of a silent alarm by authorization only or by system
control (setting, unsetting, PG control, …) when a user is in the presence
of a criminal. A Panic alarm is triggered during system control when a code
is entered with 1 mathematically added to the last digit’s value. This function
is available for codes with / without a prefix. Example: a user code with
a prefix = 4*4444, for duress access control enter 4*4445; a user code with
no prefix = 4444, for duress access control enter 4445. Caution: when
the user code’s last digit is 9 then for duress access control use 0 as a last
digit. Example: A user code with no prefix = 4449, for duress access control
enter 4440 (only enter 0 on the end).
Caution: enabling this function erase all predefined codes in the system!!!
Alarm confirmation within
one section*
If confirmation reaction by another detector is set for a detector, this
confirmation option can be used to limit confirmation to the same section only
(otherwise a detector from any section can confirm an alarm). This is valid
equally for intrusion detectors and for fire detectors.
Siren (IW output) when
tamper is triggered*
A siren with the IW response acoustically indicates a tamper alarm if the zone
is unset or partially set
Tamper alarm indication
reset by Service*
The tampering memory indication can only be reset by a service or ARC
technician. If this option is not checked, the indication may also be reset
by the Administrator (but not User).
Reset enabled*
Possibility to lock reset of the control panel with a jumper on the board. If reset
is prohibited and the service code is lost, the control panel can only be unlocked
by the manufacturer. Reset of the control panel is described in chapter
12 Reset of the control panel.
Daily reset of device
autobypass*
The option only relates to activation inputs (not tamper and error inputs).
If this option is enabled, the system will automatically reset autobypassed
devices, namely every day at 12:00. If the option is disabled, autobypass of the
device will only be reset with a status change of the section. This selection
is suitable e.g. for the use of detectors with a 24hour reaction or flood detectors
that are found in a section where setting/unsetting is not necessary.