1670 RC PG10 ON PG controls
1671 RC PG11 ON PG controls
1672 RC PG12 ON PG controls
1673 RC PG13 ON PG controls
1674 RC PG14 ON PG14 zapnuto
1675 RC PG15 ON PG controls
1676 RC PG16 ON PG controls
1677 RC PG17 ON PG controls
1678 RC PG18 ON PG controls
1679 RC PG19 ON PG controls
1680 RC PG20 ON PG controls
1681 RC PG21 ON PG controls
1682 RC PG22 ON PG controls
1683 RC PG23 ON PG controls
1684 RC PG24 ON PG controls
1685 RC PG25 ON PG controls
1686 RC PG26 ON PG controls
1687 RC PG27 ON PG controls
1688 RC PG28 ON PG controls
1689 RC PG29 ON PG controls
1690 RC PG30 ON PG controls
1691 RC PG31 ON PG controls
1692 RC PG32 ON PG controls
3101 QR Health troubles (deactivation) Burglary
3110 FR Fire alarm (deactivation) Fire
3118 FG Unconfirmed fire alarm (deactivation) Fire
3120 PR Panic (deactivation) Panic
3130 BR Instant alarm (deactivation) Burglary
3133 BR 24hr alarm (deactivation) Burglary
3134 BR Delayed alarm (deactivation) Burglary
3138 BG Unconfirmed alarm (deactivation) Burglary
3144 TR Tamper (deactivation) Tamper
3151 GR Gas leak (deactivation) Fire
3154 WR Flood alarm (deactivation) Tamper
3170 UR Special Reaction A (deactivation) Special reports
3171 UR Special Reaction B (deactivation) Special reports
3172 UR Special Reaction C (deactivation) Special reports
3173 UR Special Reaction D (deactivation) Special reports
3174 UR Not used Special reports
3175 UR Not used Special reports
3176 UR Not used Special reports
3130 UR Keybox (deactivation) Special reports
3300 ER Fault (deactivation) Faults and service events
3301 AR AC recovery Uncategorised
3302 YR Control panel backup battery OK Special reports
3306 LX Service mode exit Special reports
3313 YZ Unblocked after alarm Uncategorised
3344 YH RF interference / RF jamming (deactivation) Faults and service events
3350 YK Communication to ARC restored Uncategorised
3354 YL Event to ARC was not delivered in pre-set time (deactivation) Faults and service events
3384 XR Battery of device OK Faults and service events
3401 CL Set Setting / Unsetting
3402 CG Partially set Setting / Unsetting
3407 CQ Set remotely Setting / Unsetting
3412 LE Remote access closed Uncategorised
3417 CU Remotely partially armed Setting / Unsetting
3570 EU End of device bypass (deactivation) Uncategorised
3572 TU Tamper bypass end Tamper
3573 BU Activation bypass end Uncategorised
3574 UU End of section bypass (deactivation) Uncategorised
3578 UP Fault bypass (deactivation) Faults and service events