5. Operation check
JCX-161 BNWAS Installation Manual
111
7ZPNA4321
Event Sentence (*1)
1st stage bridge audible alarm
occurs
$BNALR,hhmmss.ss,000,A,V,C1=AUT;C2=03;C3=1*hh<CR><LF>
2nd stage remote audible alarm
occurs
$BNALR,hhmmss.ss,000,A,V,C1=AUT;C2=03;C3=2*hh<CR><LF>
3rd stage remote audible alarm
occurs
$BNALR,hhmmss.ss,000,A,V,C1=AUT;C2=03;C3=3*hh<CR><LF>
Reset signal input
SW1
$BNALR,hhmmss.ss,001,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW2
$BNALR,hhmmss.ss,002,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW3
$BNALR,hhmmss.ss,003,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW4
$BNALR,hhmmss.ss,004,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW5
$BNALR,hhmmss.ss,005,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW6
$BNALR,hhmmss.ss,006,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW7
$BNALR,hhmmss.ss,007,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW8
$BNALR,hhmmss.ss,008,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW9
$BNALR,hhmmss.ss,009,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
SW10
$BNALR,hhmmss.ss,010,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
LCD Display unit
$BNALR,hhmmss.ss,021,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Reset signal input
Serial port reset signal
$BNALR,hhmmss.ss,030,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Auto Pilot Input No. $BNALR,hhmmss.ss,100,V,A,C1=AUT;C2=03;C3=0*hh<CR><LF>
Set to Manual ON $BNALR,hhmmss.ss,021,V,V,C1=MAN;C2=03;C3=0*hh<CR><LF>
Set to Manual OFF $BNALR,hhmmss.ss,021,V,V,C1=OFF;C2=03;C3=0*hh<CR><LF>
Set to Automatic $BNALR,hhmmss.ss,021,V,V,C1=AUT;C2=03;C3=0*hh<CR><LF>
Dormant period changed $BNALR,hhmmss.ss,021,V,V,C1=AUT;C2=12;C3=0*hh<CR><LF>
Alarm received from
other navigational equipment
$BNALR,hhmmss.ss,(SEQNO),A,V,BRIDGE ALARM*hh<CR><LF>
ACK received from
other navigational equipment
$BNALR,hhmmss.ss,(SEQNO),A,A,BRIDGE ALARM*hh<CR><LF>
Alarm from other
navigational equipment restored
$BNALR,hhmmss.ss,(SEQNO),V,V,BRIDGE ALARM*hh<CR><LF>