5. Operation check
JCX-161 BNWAS Installation Manual
112
7ZPNA4321
Event Sentence (*1)
No Alarm per 55 seconds $BNALR,hhmmss.ss,000,V,V,C1=xx;C2=xx;C3=0*hh<CR><LF>
System fail $BNALR,hhmmss.ss,250,A,V,SYSTEM FAIL*hh<CR><LF>
A
C Power fail $BNALR,hhmmss.ss,251,A,V,MAIN POWER FAIL*hh<CR><LF>
DC Power fail $BNALR,hhmmss.ss,251,A,V,BACK-UP POWER
FAIL*hh<CR><LF>
Control-Unit
Communication fail
$BNALR,hhmmss.ss,253,A,V,COMMUNICATION
FAIL*hh<CR><LF>
Emergency call $BNALR,hhmmss.ss,252,A,V,EMERGENCY CALL*hh<CR><LF>
*1. When various events occur, the portion of a bold letter changes.