Verifying the Benchmarking Test Results
Purpose Verify that the necessary and desired statistical values are displayed for the benchmarking
test that is run on the configured service between Router A and Router B.
Action In operational mode, enter the run show services rpm rfc2544-benchmarking (aborted-tests
| active-tests | completed-tests | summary) command to display information about the
results of each category or state of the RFC 2544-based benchmarking test, such as
aborted tests, active tests, and completed tests, for each real-time performance
monitoring (RPM) instance.
Meaning The output displays the details of the benchmarking test that was performed. For more
information about the run show servicesrpm rfc2544-benchmarking operational command,
see show services rpm rfc2544-benchmarking in the CLI Explorer.
Related
Documentation
Configuring RFC 2544-Based Benchmarking Tests on page 1341•
• rfc2544-benchmarking on page 1698
• profiles on page 1678
• tests on page 1749
• show services rpm rfc2544-benchmarking on page 3156
• show services rpm rfc2544-benchmarking test-id on page 3161
Example: Configuring an RFC 2544-Based Benchmarking Test for UNI Direction of
Ethernet Pseudowires
This example shows how to configure the benchmarking test for the user-to-network
interface (UNI) direction of an Ethernet pseudowire service.
•
Requirements on page 1375
•
Overview on page 1376
•
Configuration on page 1377
•
Verifying the Results of the Benchmarking Test for UNI Direction of an Ethernet
Pseudowire Service on page 1383
Requirements
This example uses the following hardware and software components:
•
An ACX Series router
•
Junos OS Release 12.3X53 or later
1375Copyright © 2017, Juniper Networks, Inc.
Chapter 37: Configuring RFC 2544-Based Benchmarking Tests