announce-interval (Slave Clock)
Syntax announce-interval announce-interval-value
Hierarchy Level [edit protocols ptp slave]
Description Specify the rate of announce messages that a Precision Time Protocol (PTP) slave
requests from the master during a unicast-negotiation session. The announce interval
is configured on the slave.
NOTE: The configuration of the announce-interval statement is effective only
when the unicast-negotiation statement is also configured at the [edit
protocols ptp] hierarchy level.
Options announce-interval-value—Announce interval value for the announce messages.
Range: 0 through 3
Default: 1
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
• IEEE 1588v2 Precision Timing Protocol (PTP) on ACX Series Universal Access Routers
on page 237
• Precision Time Protocol Overview
1429Copyright © 2017, Juniper Networks, Inc.