Fig. 65 Cleaning the dirt trap
1 Cyclone separator
2 Dirt trap
3 Condensate drain hose
4 Screw plug
5 O-ring
6 Strainer
7 Condensate drain hose union nut
8 Nozzle
9 Dirt trap housing
➤ Open the left-hand door.
Cleaning the dirt trap:
1. Unscrew the plug 4 and remove the strainer.
2. Loosen the union nut 7 and detach the condensate drain hose 3 from the dirt trap.
3. Use the small screwdriver to unscrew the nozzle 8 from the dirt trap housing.
4. Clean the nozzle, strainer, screw plug, O-ring 5 and dirt trap housing 9 with cleaning solvent
or spirit.
5. Check the nozzle, strainer and O-ring for wear.
Replace components if they are heavily worn.
6. Place the strainer on the screw plug.
7. Screw in the plug making sure the O-ring seats properly.
8. Screw in the nozzle and re-attach the condensate drain hose.
Making operational:
1. Reconnect the negative battery terminal.
2. Close the door.
Starting the machine and performing a test run:
1. Switch the machine on and run it in IDLE mode for approx. 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar.
10 Maintenance
10.7 Maintenance of Optional Items
142
Operator manual Portable compressor
M 64
No.: 9_5898 26 E
RAMIRENT