8.2 Starting and stopping
Precondition No personnel are working on the machine.
All doors and siding panels are closed.
NOTICE
Serious damage to engine from cold starting sprays.
Cold-start assists, such as ether or other sprays, can cause severe engine damage.
➤ Do not use cold start sprays.
Fig. 26 Starting instruments
1 «Controller On» switch
2 «Starter switch »
– STOP/Off
– On
– Preheat
– START
3 – «Load On» key with integrated
LOAD
mode
indicating light
4
Charging indicator lamp, group alarm
lamp
5
Compressed air outlet pressure gauge
6 Temperature gauge switch
7 Operating hours counter
8 Indicator
fault on the diesel particulate filter
(Option lc only)
Notes concerning snow and ice
Considerable snow or ice may build up on the machine under low temperature conditions.
➤
Remove any snow and ice from the machine before operating.
8.2.1 Running the machine
1. Open the right-hand access door.
2. Turn the «Controller On» switch.
3. Close the door.
8 Operation