7.2.2 Special measures for re-commissioning after storage or de-commissioning
Carry out the following before every start-up after long period of storage or de-commissioning:
Storage/de-
commissioning
period longer
than:
Remedy
5 months Remove the desiccant from the openings in the air intake filters of the en‐
gine and compressor.
Check the air and oil filters.
Drain the preserving oil from the separator tank.
Fill with cooling oil.
Drain the preserving oil from the engine.
Fill up with engine oil.
Check the engine coolant level.
Check the battery charge state.
Reconnect the battery.
Check all fuel lines, engine oil lines and compressor cooling oil lines for
leaks, loose connections, wear and damage.
Clean the bodywork with a grease and dirt dissolving agent.
Check the tyre pressures.
36 months Have the overall technical condition checked by an authorised
KAESER SERVICE technician.
Tab. 67 Measures for re-commissioning the compressor after a long period of storage or de-commissioning
7.3 Checking installation and operating conditions
Check and confirm all the items in the checklist before starting the machine.
Check See chapter Confirmed?
Are the operators fully conversant with safety regulations?
Have all the positioning conditions been fulfilled? 5
Is there sufficient cooling oil in the separator tank? 10.4.1
Is there sufficient oil in the engine? 10.3.4
Is the maintenance indicator on the air intake filters (engine and
compressor) OK?
10.3.2,
10.4.7
Is there sufficient coolant in the coolant expansion tank? 10.3.1
Is there sufficient fuel in the fuel tank?
Is there sufficient tool oil in the tool lubricator? (Option ec) 10.7.1
Is there enough antifreeze in the frost protector? (Option ba) 10.7.5
Are the access doors closed and all body panels in place?
Are the tyre pressures OK?
Tab. 68 Positioning and operating conditions checklist