4. Open the outlet valves.
5.
Open the left-hand door.
6. Check the cyclone separator housing and hose line for leaks.
7. Close the door.
10.7.3 Option dd
Combination filter maintenance
Precondition The machine is switched off.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
All compressed air consumers are disconnected and the air outlet valves are open.
WARNING
Danger of injury from compressed air!
Filter combination is pressurised during operation. Serious injury can result from loosening
or opening components under pressure.
➤
Wait until the machine has automatically vented (check: pressure gauge reads 0 bar!
➤ De-pressurise the combination filter.
Fig. 66 Filter combination
1 Filter combination
2 Shut-off valve condensate drain
10 Maintenance
10.7 Maintenance of Optional Items
No.: 9_5898 26 E
Operator manual Portable compressor
M 64
143
Option dd