Material Antifreeze: Antifreeze protection for air brake systems
z. B. Wabcothyl (part no. 9.5400.0)
Cleaning cloths
Precondition The machine is switched off.
The machine is fully vented, the pressure gauge reads 0 bar.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
DANGER
Spontaneous ignition of anti-freeze!
Risk of fire and explosion caused by spontaneous ignition can cause severe injury.
➤
Never top up antifreeze unless the machine is stopped and cooled down.
WARNING
Danger of injury from compressed air!
The frost protector is pressurised during operation. Serious injury can result from loosening
or opening components under pressure.
➤
Wait until the machine has automatically vented (check: pressure gauge reads 0 bar!
Fig. 69 Filling the frost protector
1 Frost protector clamp ring
2 Frost protector bowl
3 Antifreeze container
1. Open the right-hand access door.
2. Unscrew the clamp ring and remove the bowl.
3. Fill the bowl ¾ full with antifreeze.
4. Screw the bowl carefully back into place.
5. Close the door.