NO KNOWN NODES
An NDHEARD list has been requested and the TNC has not heard any other
nodes (e.g., KA-Nodes).
NOT ENOUGH RAM
This message indicates that you have attempted to set the NUMNODES,
MAXUSERS, or PBBS to a value which requires more RAM memory than is
currently available. It may also occur if you try to enable the MYREMOTE
and there isn’t enough memory left.
Not while connected
Some parameters cannot be changed if the TNC is connected to another sta
-
tion. This message is printed if an attempt is made.
PIC ID xx
This message, which appears during a hard reset, indicates the PIC processor
version.
PBBS MESSAGE BUFFER NOT VALID!
TRYING TO RECOVER
When you turn on the TNC a check is made of the pointers relating to the
PBBS. It appears that one or more of these pointers may not be correct. An
attempt is made to correct them, but it is possible that some or all of the mes-
sages may be lost.
PRESS (*) TO SET BAUD RATE
You need to press the asterisk (*) key on your keyboard within two seconds
of seeing this message. The TNCs autobaud routine will then detect what
baud rate your computer is using, so the two devices can communicate.
....RAM OK
xxxK BYTES
This message appears when a hard reset is performed and indicates that the
TNC has tested the installed RAM and has found no problems. It also reports
the amount of RAM installed in your TNC.
Appendix E: Additional Information Messages from the KAM’98
User’s Guide 356 KAM’98 v 8.3