Instructions for use
ELECTROmatic TM and TMM/TMC

Table of Contents

Questions and Answers

  • Z
    Zoe BradleySep 23, 2025
    What to do for all other events on KaVo ELECTROmatic TM?
    • M
      Michael JohnsonSep 23, 2025
      If you encounter any other events on your KaVo dental equipment, it indicates an internal system error. Turn the unit off and then on again. If the error persists, contact a service engineer.
  • W
    William LoweAug 23, 2025
    What to do if SAFEdrive icon flashes yellow on KaVo Dental equipment?
    • L
      lucassarahAug 23, 2025
      If the SAFEdrive icon flashes yellow, indicating the motor is overloaded, especially if you're using a third-party handpiece, deactivate SAFEdrive or use a KaVo high-speed handpiece. If using a KaVo high-speed handpiece, relieve the load on the handpiece for at least 2 seconds by lifting it off the tooth. Once the motor reaches maximum speed and the icon turns yellow, continue working in intermittent mode.
  • K
    Kevin ClarkAug 25, 2025
    Why is there no or insufficient spray water in my KaVo ELECTROmatic TM Dental equipment?
    • W
      Wayne PorterAug 26, 2025
      There could be several reasons for insufficient spray water: - The spray water regulation might be closed; in this case, open the spray water fully. - The water line may be soiled; to resolve this, pull off the handpiece and actuate the spray water in bursts to rinse it. - The filter insert could be soiled; if so, replace the filter on the water inlet. - The spray water on the treatment unit or foot control might be closed; open the spray on the treatment unit. If the problem continues, unscrew the turbine hose to check for water flow. If there's no flow, contact a service engineer.
  • S
    smithlaurenAug 27, 2025
    What to do if my KaVo ELECTROmatic TM Dental equipment malfunctions with no display and the LED on the rear of the device does not flash?
    • K
      Kathleen BlackAug 27, 2025
      If your device malfunctions with no display and the LED on the rear doesn't flash, it may be due to no voltage supply. Check and restore the voltage supply and ensure the connection is correct. Check that the standby LED on the power supply is on. If it's not on, replace the power supply. If the problem persists, contact a service engineer.
  • C
    Clarence BoydAug 27, 2025
    What to do if my KaVo ELECTROmatic TM malfunctions with no display and the LED on the rear of the device flashes?
    • M
      Michael MorganAug 27, 2025
      If your device malfunctions (no display, the LED on the rear of the device flashes), this may indicate no voltage supply to the control panel. Check and restore the correct connection. If this doesn't resolve the issue, try replacing the connection cable to the control panel, or replacing the control panel itself. If the problem continues, notify a service engineer.
  • E
    eclarkeSep 17, 2025
    What to do if KaVo ELECTROmatic TM Dental equipment device malfunctions (no display, the LED on the rear of the device flashes)?
    • M
      Matthew JohnsonSep 17, 2025
      If your KaVo dental equipment malfunctions with no display but the LED on the rear flashes, it suggests there's no voltage supply to the control panel or no connection to it. Check and restore the correct connection. If that doesn't work, replace the connection cord to the control panel or replace the control panel itself. If problems continue, contact a service engineer.
  • N
    nathanyoungSep 14, 2025
    What to do if KaVo ELECTROmatic TM device malfunctions (no display, the LED on the rear of the device does not flash)?
    • L
      Leslie HollowaySep 14, 2025
      If your KaVo dental equipment malfunctions with no display and the LED on the rear doesn't flash, the cause might be no voltage supply. Check and restore the correct voltage supply and connection. Ensure the standby LED on the power supply is lit. If it's not, replace the power supply. If the issue continues, contact a service engineer.
  • T
    Tracy Martinez DDSSep 15, 2025
    Why maximum speed is not reached on KaVo Dental equipment?
    • M
      Martha JohnsonSep 15, 2025
      If your KaVo dental equipment isn't reaching maximum speed, it could be due to a few reasons. The supply pressure might have dropped significantly; try repeatedly pushing the foot control down fully to allow the motor to start up and calibrate automatically, increasing the speed. Alternatively, there might be a kink or leak in the supply hose; remove any kinks and inspect for damage, replacing the hose if necessary. Lastly, the motor or handpiece could be sluggish, in which case you should replace or repair the handpiece. If the issue persists, contact a service engineer.
  • V
    Virginia ElliottSep 6, 2025
    What does Event E9, E46 mean on KaVo Dental equipment?
    • D
      David WatersSep 6, 2025
      Event E9 or E46 indicates that communication between the motor control and panel is interrupted. This may occur when you reset to factory settings and should reset automatically. If the error persists, switch the device off and on again. If the error persists, notify the service engineer.
  • F
    fthomasSep 3, 2025
    What does Event E5 mean on KaVo ELECTROmatic TM?
    • M
      michael85Sep 3, 2025
      Event E5 indicates an automatic light and motor shut-off during continuous operation of the motor. Ensure you comply with the defined operating mode.

Summary

User Instructions Overview

User Guide and Documentation

Provides essential guidance for safe and correct operation of the device.

Target Audience and Service Information

Identifies intended users and outlines service procedures and contact details.

Warranty, Transport, and Disposal

Details warranty terms, procedures for handling transport damage, and disposal guidelines.

Safety Precautions and Hazards

General Safety Warnings

Covers infection, explosion, electrical hazards, and ingress of liquids.

Device Condition and Personnel Qualification

Specifies user qualifications, service requirements, and safe handling practices.

Electromagnetic Field Information

Addresses potential interference with medical systems and necessary precautions.

Product Description and Specifications

Intended Use and Product Versions

Defines the device's purpose, proper use, and available configurations.

Scope of Delivery Details

Lists included components and accessories for different ELECTROmatic models.

Control Panel and Operating Modes

Explains the touch display, modes, and operating controls.

Technical Specifications

Provides detailed technical data, including dimensions, power, and environmental requirements.

Installation Guide

Location and Mounting Positions

Guides on selecting the installation site and available mounting options.

Preparation and Connection Steps

Details steps for preparing the device, connecting components, and checking installation.

Startup and Configuration

Connection Conditions and Requirements

Outlines necessary conditions for compressed air, water, and electrical connections.

Motor and Foot Control Setup

Covers connecting the motor, hoses, and calibrating the foot control.

Device Settings Configuration

Explains how to adjust parameters like brightness, volume, and file settings.

Operation Modes

Switching On;Off and Basic Operation

Covers powering the unit on/off and understanding the display.

PREP Mode Functions

Details speed settings, transmission ratios, and SAFEdrive function in PREP mode.

ENDO Mode and File Management

Explains ENDO mode operation, file database, and sequence customization.

Decommissioning and Reprocessing

Disconnecting and Unplugging Procedures

Provides steps for safely disconnecting the device and its components.

Cleaning and Disinfection Procedures

Details manual cleaning, disinfection, and germ reduction steps.

Storage and Post-Preparation Checks

Covers proper storage and essential checks after reprocessing.

Servicing and Maintenance

Changing the Water Filter

Step-by-step guide for replacing the water filter insert.

Replacing LED Lamps

Instructions for replacing LED lamps in motors and bases.

Replacing Motor Hose

Procedure for replacing a defective motor hose.

Troubleshooting Common Issues

Malfunctions and Remedies

Lists potential issues, causes, and solutions for device operation.

Accessories and Consumables

List of Available Parts

Catalog of compatible accessories and consumable parts with material numbers.

Electromagnetic Compatibility (EMC)

Emission Guidelines and Declarations

Manufacturer's declaration on electromagnetic emissions per standards.

Immunity Statements and Safe Distances

Information on device immunity and recommended distances for communication equipment.

KaVo ELECTROmatic TM Specifications

General IconGeneral
TypeElectric Micromotor System
Foot ControlVariable Speed Foot Control
Noise LevelLow Noise Operation
SpeedUp to 40, 000 RPM
CompatibilityKaVo handpieces
Handpiece ConnectionISO 3964
DisplayDigital display
Autoclavable ComponentsHandpieces and some attachments
Supply voltage100-240V AC, 50/60Hz